Child level: [Definition] C28 - Temperature gradient uncertainty Answer:
ID
C28
Field name
Temperature gradient uncertainty
Short name
T_grad_uncertainty
Unit
K/km
Field type
Float (2 decimal places)
Obligation
R
Level
C
Domain
B,S
Group
Temp
Quality relevance
-
Field Description
Uncertainty (one standard deviation) of mean measured temperature gradient [T_grad_mean] as estimated by an error ...
Child level: [Definition] C29 - Mean temperature gradient corrected Answer:
ID
C29
Field name
Mean temperature gradient corrected
Short name
T_grad_mean_cor
Unit
K/km
Field type
Float (2 decimal places)
Obligation
O
Level
C
Domain
B,S
Group
Temp
Quality relevance
-
Field Description
Mean temperature gradient corrected for borehole (drilling/mud circulation) and environmental effects (terrain effects/topography, sedimentation, ...
Child level: [Definition] C30 - Corrected temperature gradient uncertainty Answer:
ID
C30
Field name
Corrected temperature gradient uncertainty
Short name
T_grad_uncertainty_cor
Unit
K/km
Field type
Float (2 decimal places)
Obligation
O
Level
C
Domain
B,S
Group
Temp
Quality relevance
-
Field Description
Uncertainty (one standard deviation) of mean corrected temperature gradient [T_grad_mean_cor] as estimated by an ...
Child level: [Definition] C31 - Temperature method (top) Answer:
ID
C31
Field name
Temperature method (top)
Short name
T_method_top
Unit
-
Field type
Char (255)
Obligation
M
Level
C
Domain
B
Group
Temp
Quality relevance
M score
Field Description
Method used for temperature determination at the top of the heat-flow determination interval.
Allowed range of values
[LOGeq][LOGpert][cLOG][DTSeq][DTSpert][cDTS][BHT][cBHT][DST][cDST][RTDeq][RTDpert][cRTD][CPD][XEN][GTM][BSR][ODTT-PC][ODTT-TP][SUR][Other ...
Child level: [Definition] C32 - Temperature method (bottom) Answer:
ID
C32
Field name
Temperature method (bottom)
Short name
T_method_bottom
Unit
-
Field type
Char (255)
Obligation
M
Level
C
Domain
B
Group
Temp
Quality relevance
M score
Field Description
Method used for temperature determination at the bottom of the heat-flow determination interval.
Allowed range of values
[LOGeq][LOGpert][cLOG][DTSeq][DTSpert][cDTS][BHT][cBHT][DST][cDST][RTD][CPD][XEN][GTM][BSR][ODTT-PC][ODTT-TP][Other ...
Child level: [Definition] C33 - Shut-in time (top) Answer:
ID
C33
Field name
Shut-in time (top)
Short name
T_shutin_top
Unit
hours
Field type
Integer (5)
Obligation
R
Level
C
Domain
B
Group
Temp
Quality relevance
-
Field Description
Time of measurement at the interval top in relation to the end values measured during the drilling ...
Child level: [Definition] C34 - Shut-in time (bottom) Answer:
ID
C34
Field name
Shut-in time (bottom)
Short name
T_shutin_bottom
Unit
hours
Field type
Integer (5)
Obligation
R
Level
C
Domain
B
Group
Temp
Quality relevance
-
Field Description
Time of measurement at the interval bottom in relation to the end values measured during the drilling ...
Child level: [Definition] C35 - Temperature correction method (top) Answer:
ID
C35
Field name
Temperature correction method (top)
Short name
T_corr_top
Unit
-
Field type
Char (255)
Obligation
R
Level
C
Domain
B
Group
Temp
Quality relevance
-
Field Description
Applicable only if gradient correction for borehole effects is reported. Approach applied to correct the temperature ...
Child level: [Definition] C36 - Temperature correction method (bottom) Answer:
ID
C36
Field name
Temperature correction method (bottom)
Short name
T_corr_bottom
Unit
-
Field type
Char (255)
Obligation
R
Level
C
Domain
B
Group
Temp
Quality relevance
-
Field Description
Applicable only if gradient correction for borehole effects is reported. Approach applied to correct the temperature ...
Child level: [Definition] C37 - Number of temperature recordings Answer:
ID
C37
Field name
Number of temperature recordings
Short name
T_number
Unit
-
Field type
Integer (6)
Obligation
M
Level
C
Domain
B,S
Group
Temp
Quality relevance
M score
Field Description
Number of discrete temperature points (e.g. number of used BHT values, log values or thermistors ...